Healicom FCA161 Fully Automated Biochemistry Analyzer
Quick Details
- Type: Biochemical Analysis System
- Brand Name: Healicom
- Model Number: FCA161
- Place of Origin: Jiangsu, China
- Instrument classification: Class II
- Warranty: 1 Year
- After-sale Service: Online technical support
- Reading System: Direct reading system
- Assay Item: 36 assay items
- Sample Volume: 1-100uL, 0.1uL/step
- Reagent Position: 36 positions
- Wavelength: 340-810nm
Features 1. No touch mixing function, greatly reducing water consumption and decreasing carry-over. 2. Lower reagent consumption technology, greatly saving reagent’s production, transportation and storage cost, and decreasing carry-over (On request, down to 80ul/test) 3. New cooling system, steadily keeping reagent chamber in 2-8℃. 4. Auto perameter setting function.
Operation
|
Random access
|
Reading System
|
Direct reading system
|
Method
|
End point, Kinetic, Fixed time, Bi-chromatic, Immunoturbidimetric,
1-2 reagent multistandard, reagent/serum blank, etc |
Assay Item
|
36 assay items
|
Throughput
|
1 Reagent: 200 tests/h (max)
|
2 Reagent: 150 tests/h (max)
|
|
With ISE: 100 tests/h
|
|
Sample Position
|
50 postions
|
including standard, control stat; either serum cup or primary tube available
|
|
Sample Volume
|
1-100µL, 0.1µL/step
|
Reagent Position
|
36 positions
|
Reagent Volume
|
1µL-500µL, 0.1µL/step
|
Reagent/Sample Probe
|
With liquid level sensor, collision sensor
|
Reaction Time
|
0-999seconds
|
Cuvette
|
High quality UV-transmitted plastic cuvette, or quartz glass cuvette on request
|
Cuvette Time
|
5 channels automatic washing system for reaction cuvettes
|
Independent washing station for each sample/reagent probe and mixer
|
|
Alarm
|
Automatic alarm for malfuction (e.g: collision, reagent and distilled water insufficiency, waste container ful, etc)
|
Calibration
|
Linear, Non-linear, Multi point, K factor
|
Sample Dilution/Retest
|
Sample can be diluted and retested if results are out of range or sample is insufficient
|
Wavelength
|
340-810nm
|
Light Source
|
Halogen lamp
|
Absorbance Resolution
|
0.0001A
|
Absorbance Accuracy
|
±0.0003A(0~2.5A)
|
Repeatablility (CV%)
|
ALT<3%, UREA<2.5%, TP<1.5%
|
Quality Control
|
Levy jennings quality control program at 3 levels
|
Bar Code
|
Optional
|
Printer
|
Multiple report formats available
|
Other
|
Tele-diagnostic, bi-direction interface to LIS syste, etc
|
Language
|
English, French, Spanish, German, Russian, etc
|
System
|
Windows XP or Vista
|
Power Supply
|
220V/50Hz, or 110V/60Hz
|
Dimension
|
65 x 53 x 52cm
|
Weight
|
50Kg
|
Contact Us :
Call 24/7 : 880 1842-756014
Email : technohealthbd@gmail.com
Facebook | Instagram | YouTube
Head Office :
House #42, Lake Drive Road, Sector 07, Uttara, Dhaka-1230
Head office Contact : 880 1842-756014
Show Room :
Bagdad Surgical Market, Shop No (7-8) 21/A 1 st Floor, Mahbub Plaza, Topkhana Road, Dhaka- 1000
Show Room Contact : 880 181275-4847
Reviews
There are no reviews yet.